Technical Information
Technical Information
Downloads
- Section from Centre Line (PDF)
- Backstage LX Plan (PDF)
- Backstage Theatre Plan (PDF)
- Studio technical spec (PDF)
Sound
| Mixer: | Dynacord CMS 1600 16 channel mixer with integrated EQ and effects. |
| Patch panel: | 16 channel – Located Down Stage Right |
| Amplifiers: | Dynacord 1000W Dynacord 12000 W PV 550 W x 2 For bass bins |
| MICS: | 3 Audio technic rifle mics 2 x EV 267a/as handheld vocal mic 1 x Leem SR-305 handheld vocal mic 4 mic. Stands |
Cans
Master station located in control room with links to SL and SR with four additional belt packs available. Show relay to dressing room corridor only.
Playback
- 1 AIWA Twin Cassette Deck
- 2 x Sony single mini disc players one with auto pause
- 1 Sony 5 carousel CD player
- 2 Dynacord 300 W speakers located FOH
- 2 Dynacord 150 W Speakers located mid auditorium
- 2 Dynacord 400W bass bins
- Monitors- 2 x Dynacord AM12 360 W active cabinets
Lighting
Over Stage Lighting Grid
This consists of ten bars in all including five electric drill operated winch bars and five fixed bars. The electric drill operated bars include three 15 amp internally wired bars which can be interchanged. The maximum distributed loading on any one bar is 250kg SWL. The maximum height on the lowest bar is 5.17m.
For a full CAD drawing of the stage area see the downloads above.
Front of House Gantry
Steel Gantry with fourteen 15amp circuits. – Access ladders from stage left & right and from both floor levels crossing the auditorium.
Control System
Strand Classic Palette 150
Swisson DMX tester as riggers remote
Dimmers
L.D. 90 10m digital dimmer 72 Sockets & 72 Dimmers
Lantern List
- Cantata F 1200w x 12
- Cantata PC 1200w x 4
- Selcon Rama F 1200w x 13
- Cantata 18/32 1200w x 6
- Cantata 11/26 1200w x 4
- ETC Source 4 Profile 25/50 x 5
- Parcan Par 64 1000w x 21
- IRIS Floods 1250W x 12
General Facilities
Stage Left / Lower Level
Capacity: 214
Dressing Room:
- Two purpose designed dressing rooms complete with electric
showers, mirrors, lights, wash-hand basins etc. - Separate toilets with wash hand basins
- Iron & Ironing board
Wash Rooms: Male & Female
Green Room:
Stage Right / Lower Level
Wash Rooms: Both ladies and gentlemens toilets with wash hand basin
Laundry Room: Washing machine
Ironing boards and irons
Plant & Tool Room: Limited access area
Get-In-Area: Large area with flat/direct access to stage via 2 automatic shutter doors, work room and set building & storage facilities
STAGE DOOR ENTRANCE FROM REAR CAR PARK